{ "info": { "author": "Gino Ledesma", "author_email": "gledesma@gmail.com", "bugtrack_url": null, "classifiers": [ "Environment :: Console", "Environment :: Web Environment", "Intended Audience :: Developers", "License :: OSI Approved :: MIT License", "Programming Language :: Python :: 2", "Programming Language :: Python :: 2.7", "Programming Language :: Python :: 3", "Programming Language :: Python :: 3.4", "Programming Language :: Python :: 3.5", "Programming Language :: Python :: 3.6" ], "description": "About\n=====\n\nA Prometheus exporter for the SunPower ProVision monitoring system:\n\n- SunPower PVS 5x\n- SunPower PVS 6\n\nRequirements\n============\n\n- Python 2.7+\n- Prometheus Client\n\nInstallation\n============\n\nFrom pip:\n```\npip install sunpower_pvs_exporter\n```\n\nFrom github:\n```\n# pip install git@github.apple.com:ginoledesma/sunpower-pvs-exporter.git\npip install sunpower_pvs_exporter\n```\n\nUsage\n=====\n\n\nHelp\n----\n```\n$ sunpower-pvs-exporter -h \nusage: sunpower-pvs-exporter [-h] [--hostname HOSTNAME] [--port PORT]\n [--use-tls] [--listen-on LISTEN_ON]\n [--log-file LOG_FILE]\n [--log-level {ERROR,WARNING,INFO,DEBUG}]\n [--timeout TIMEOUT] [--use-device-data-timestamp]\n\noptional arguments:\n -h, --help show this help message and exit\n --hostname HOSTNAME SunPower PV Supervisor hostname\n --port PORT SunPower PV Supervisor port\n --use-tls Use SSL/TLS when communicating with SunPower PV\n Supervisor\n --listen-on LISTEN_ON\n Listen on the specified port\n --log-file LOG_FILE Output logfile\n --log-level {ERROR,WARNING,INFO,DEBUG}\n Log level\n --timeout TIMEOUT Connection timeout value (in seconds)\n --use-device-data-timestamp\n Use the data timestamp from the PVS device\n```\n\nRuntime \n-------\n```\n$ sunpower-pvs-exporter\n2019-05-13 20:13:48,701 Listening on port 9110...\n\n$ curl http://localhost:9110/\n# HELP python_info Python platform information\n# TYPE python_info gauge\npython_info{implementation=\"CPython\",major=\"2\",minor=\"7\",patchlevel=\"10\",version=\"2.7.10\"} 1.0\n# HELP sunpower_pvs_communication_interface_info Communications Interface Information\n# TYPE sunpower_pvs_communication_interface_info gauge\nsunpower_pvs_communication_interface_info{interface=\"wan\",internet=\"up\",sms=\"reachable\"} 1.0\nsunpower_pvs_communication_interface_info{interface=\"plc\",internet=\"down\",sms=\"unreachable\"} 1.0\nsunpower_pvs_communication_interface_info{interface=\"sta0\",internet=\"down\",sms=\"unreachable\"} 1.0\nsunpower_pvs_communication_interface_info{interface=\"cell\",internet=\"down\",sms=\"unreachable\"} 1.0\n# HELP sunpower_pvs_grid_profile_info Grid Profile\n# TYPE sunpower_pvs_grid_profile_info gauge\nsunpower_pvs_grid_profile_info{id=\"aabbccddeeffaabbccddeeffaabbccddeeffaabbccd\",name=\"IEEE-1547\",percent=\"100\",status=\"success\"} 1.0\n# HELP sunpower_pvs_supervisor_communication_errors_total Total number of communication errors\n# TYPE sunpower_pvs_supervisor_communication_errors_total counter\nsunpower_pvs_supervisor_communication_errors_total{device_id=\"ZT01234567890123456\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\"} 283.0\n# HELP sunpower_pvs_supervisor_cpu_loadavg CPU Load Average\n# TYPE sunpower_pvs_supervisor_cpu_loadavg gauge\nsunpower_pvs_supervisor_cpu_loadavg{device_id=\"ZT01234567890123456\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\"} 0.2\n# HELP sunpower_pvs_supervisor_errors_total Total number of errors\n# TYPE sunpower_pvs_supervisor_errors_total counter\nsunpower_pvs_supervisor_errors_total{device_id=\"ZT01234567890123456\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\"} 0.0\n# HELP sunpower_pvs_supervisor_flash_storage_available_bytes Storage available space (bytes)\n# TYPE sunpower_pvs_supervisor_flash_storage_available_bytes gauge\nsunpower_pvs_supervisor_flash_storage_available_bytes{device_id=\"ZT01234567890123456\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\"} 7.8512128e+07\n# HELP sunpower_pvs_supervisor_mem_used_bytes Memory used (bytes)\n# TYPE sunpower_pvs_supervisor_mem_used_bytes gauge\nsunpower_pvs_supervisor_mem_used_bytes{device_id=\"ZT01234567890123456\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\"} 3.9350272e+07\n# HELP sunpower_pvs_supervisor_scan_time_seconds Scan time\n# TYPE sunpower_pvs_supervisor_scan_time_seconds gauge\nsunpower_pvs_supervisor_scan_time_seconds{device_id=\"ZT01234567890123456\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\"} 0.0\n# HELP sunpower_pvs_supervisor_skipped_scans_total Skipped scans\n# TYPE sunpower_pvs_supervisor_skipped_scans_total counter\nsunpower_pvs_supervisor_skipped_scans_total{device_id=\"ZT01234567890123456\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\"} 0.0\n# HELP sunpower_pvs_supervisor_untransmitted_events_total Untransmitted events\n# TYPE sunpower_pvs_supervisor_untransmitted_events_total counter\nsunpower_pvs_supervisor_untransmitted_events_total{device_id=\"ZT01234567890123456\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\"} 9510.0\n# HELP sunpower_pvs_supervisor_uptime_seconds_total Uptime (seconds)\n# TYPE sunpower_pvs_supervisor_uptime_seconds_total counter\nsunpower_pvs_supervisor_uptime_seconds_total{device_id=\"ZT01234567890123456\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\"} 10494.0\n# HELP sunpower_pvs_power_meter_ct_rated_current_amperes CT Rated Current\n# TYPE sunpower_pvs_power_meter_ct_rated_current_amperes gauge\nsunpower_pvs_power_meter_ct_rated_current_amperes{ct_rated_current=\"50\",description=\"Power Meter PVS6M01234567p\",device_id=\"PVS6M01234567p\",mode=\"production\",model=\"PVS6M0001p\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-P\"} 50.0\nsunpower_pvs_power_meter_ct_rated_current_amperes{ct_rated_current=\"100\",description=\"Power Meter PVS6M01234567c\",device_id=\"PVS6M01234567c\",mode=\"consumption\",model=\"PVS6M0001c\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-C\"} 100.0\n# HELP sunpower_pvs_power_meter_ac_frequency_hertz AC Frequency\n# TYPE sunpower_pvs_power_meter_ac_frequency_hertz gauge\nsunpower_pvs_power_meter_ac_frequency_hertz{ct_rated_current=\"50\",description=\"Power Meter PVS6M01234567p\",device_id=\"PVS6M01234567p\",mode=\"production\",model=\"PVS6M0001p\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-P\"} 60.0\nsunpower_pvs_power_meter_ac_frequency_hertz{ct_rated_current=\"100\",description=\"Power Meter PVS6M01234567c\",device_id=\"PVS6M01234567c\",mode=\"consumption\",model=\"PVS6M0001c\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-C\"} 60.0\n# HELP sunpower_pvs_power_meter_net_energy_watt_hours Total Net Energy\n# TYPE sunpower_pvs_power_meter_net_energy_watt_hours gauge\nsunpower_pvs_power_meter_net_energy_watt_hours{ct_rated_current=\"50\",description=\"Power Meter PVS6M01234567p\",device_id=\"PVS6M01234567p\",mode=\"production\",model=\"PVS6M0001p\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-P\"} 294370.0\nsunpower_pvs_power_meter_net_energy_watt_hours{ct_rated_current=\"100\",description=\"Power Meter PVS6M01234567c\",device_id=\"PVS6M01234567c\",mode=\"consumption\",model=\"PVS6M0001c\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-C\"} -103980.0\n# HELP sunpower_pvs_power_meter_average_real_power_watts Average real power\n# TYPE sunpower_pvs_power_meter_average_real_power_watts gauge\nsunpower_pvs_power_meter_average_real_power_watts{ct_rated_current=\"50\",description=\"Power Meter PVS6M01234567p\",device_id=\"PVS6M01234567p\",mode=\"production\",model=\"PVS6M0001p\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-P\"} 9.0\nsunpower_pvs_power_meter_average_real_power_watts{ct_rated_current=\"100\",description=\"Power Meter PVS6M01234567c\",device_id=\"PVS6M01234567c\",mode=\"consumption\",model=\"PVS6M0001c\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-C\"} 464.1\n# HELP sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive Average reactive power\n# TYPE sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive gauge\nsunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive{ct_rated_current=\"50\",description=\"Power Meter PVS6M01234567p\",device_id=\"PVS6M01234567p\",mode=\"production\",model=\"PVS6M0001p\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-P\"} 328.0\nsunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive{ct_rated_current=\"100\",description=\"Power Meter PVS6M01234567c\",device_id=\"PVS6M01234567c\",mode=\"consumption\",model=\"PVS6M0001c\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-C\"} -915.6\n# HELP sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive Average reactive power\n# TYPE sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive gauge\nsunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive{ct_rated_current=\"50\",description=\"Power Meter PVS6M01234567p\",device_id=\"PVS6M01234567p\",mode=\"production\",model=\"PVS6M0001p\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-P\"} 329.40000000000003\nsunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive{ct_rated_current=\"100\",description=\"Power Meter PVS6M01234567c\",device_id=\"PVS6M01234567c\",mode=\"consumption\",model=\"PVS6M0001c\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-C\"} 1077.3999999999999\n# HELP sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power Power Factor (Real Power / Apparent Power) ratio\n# TYPE sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power gauge\nsunpower_pvs_power_meter_power_factor_real_power_per_apparent_power{ct_rated_current=\"50\",description=\"Power Meter PVS6M01234567p\",device_id=\"PVS6M01234567p\",mode=\"production\",model=\"PVS6M0001p\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-P\"} 0.0241\nsunpower_pvs_power_meter_power_factor_real_power_per_apparent_power{ct_rated_current=\"100\",description=\"Power Meter PVS6M01234567c\",device_id=\"PVS6M01234567c\",mode=\"consumption\",model=\"PVS6M0001c\",port=\"\",software_version=\"3000\",type=\"PVS5-METER-C\"} 0.4302\n# HELP sunpower_pvs_inverter_ac_current_amperes AC Current\n# TYPE sunpower_pvs_inverter_ac_current_amperes gauge\nsunpower_pvs_inverter_ac_current_amperes{description=\"Inverter E00000000000001\",device_id=\"E00000000000001\",model=\"AC_Module_Type_E\",module_id=\"P07M20205372\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.0\nsunpower_pvs_inverter_ac_current_amperes{description=\"Inverter E00000000000002\",device_id=\"E00000000000002\",model=\"AC_Module_Type_E\",module_id=\"P07M20205351\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.0\nsunpower_pvs_inverter_ac_current_amperes{description=\"Inverter E00000000000003\",device_id=\"E00000000000003\",model=\"AC_Module_Type_E\",module_id=\"P07M20205226\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.0\n# HELP sunpower_pvs_inverter_ac_power_watts AC Power\n# TYPE sunpower_pvs_inverter_ac_power_watts gauge\nsunpower_pvs_inverter_ac_power_watts{description=\"Inverter E00000000000001\",device_id=\"E00000000000001\",model=\"AC_Module_Type_E\",module_id=\"P07M20205372\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.1\nsunpower_pvs_inverter_ac_power_watts{description=\"Inverter E00000000000002\",device_id=\"E00000000000002\",model=\"AC_Module_Type_E\",module_id=\"P07M20205351\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.4\nsunpower_pvs_inverter_ac_power_watts{description=\"Inverter E00000000000003\",device_id=\"E00000000000003\",model=\"AC_Module_Type_E\",module_id=\"P07M20205226\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.0\n# HELP sunpower_pvs_inverter_ac_voltage_volts AC Voltage\n# TYPE sunpower_pvs_inverter_ac_voltage_volts gauge\nsunpower_pvs_inverter_ac_voltage_volts{description=\"Inverter E00000000000001\",device_id=\"E00000000000001\",model=\"AC_Module_Type_E\",module_id=\"P07M20205372\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 250.48\nsunpower_pvs_inverter_ac_voltage_volts{description=\"Inverter E00000000000002\",device_id=\"E00000000000002\",model=\"AC_Module_Type_E\",module_id=\"P07M20205351\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 249.98\nsunpower_pvs_inverter_ac_voltage_volts{description=\"Inverter E00000000000003\",device_id=\"E00000000000003\",model=\"AC_Module_Type_E\",module_id=\"P07M20205226\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 250.16\n# HELP sunpower_pvs_inverter_dc_current_amperes DC Current\n# TYPE sunpower_pvs_inverter_dc_current_amperes gauge\nsunpower_pvs_inverter_dc_current_amperes{description=\"Inverter E00000000000001\",device_id=\"E00000000000001\",model=\"AC_Module_Type_E\",module_id=\"P07M20205372\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.01\nsunpower_pvs_inverter_dc_current_amperes{description=\"Inverter E00000000000002\",device_id=\"E00000000000002\",model=\"AC_Module_Type_E\",module_id=\"P07M20205351\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.03\nsunpower_pvs_inverter_dc_current_amperes{description=\"Inverter E00000000000003\",device_id=\"E00000000000003\",model=\"AC_Module_Type_E\",module_id=\"P07M20205226\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.03\n# HELP sunpower_pvs_inverter_dc_power_watts DC Power\n# TYPE sunpower_pvs_inverter_dc_power_watts gauge\nsunpower_pvs_inverter_dc_power_watts{description=\"Inverter E00000000000001\",device_id=\"E00000000000001\",model=\"AC_Module_Type_E\",module_id=\"P07M20205372\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.1\nsunpower_pvs_inverter_dc_power_watts{description=\"Inverter E00000000000002\",device_id=\"E00000000000002\",model=\"AC_Module_Type_E\",module_id=\"P07M20205351\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.6\nsunpower_pvs_inverter_dc_power_watts{description=\"Inverter E00000000000003\",device_id=\"E00000000000003\",model=\"AC_Module_Type_E\",module_id=\"P07M20205226\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 0.8\n# HELP sunpower_pvs_inverter_dc_voltage_volts DC Voltage\n# TYPE sunpower_pvs_inverter_dc_voltage_volts gauge\nsunpower_pvs_inverter_dc_voltage_volts{description=\"Inverter E00000000000001\",device_id=\"E00000000000001\",model=\"AC_Module_Type_E\",module_id=\"P07M20205372\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 10.12\nsunpower_pvs_inverter_dc_voltage_volts{description=\"Inverter E00000000000002\",device_id=\"E00000000000002\",model=\"AC_Module_Type_E\",module_id=\"P07M20205351\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 21.99\nsunpower_pvs_inverter_dc_voltage_volts{description=\"Inverter E00000000000003\",device_id=\"E00000000000003\",model=\"AC_Module_Type_E\",module_id=\"P07M20205226\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 21.99\n# HELP sunpower_pvs_inverter_operating_frequency_hertz Operating Frequency (hertz)\n# TYPE sunpower_pvs_inverter_operating_frequency_hertz gauge\nsunpower_pvs_inverter_operating_frequency_hertz{description=\"Inverter E00000000000001\",device_id=\"E00000000000001\",model=\"AC_Module_Type_E\",module_id=\"P07M20205372\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 60.19\nsunpower_pvs_inverter_operating_frequency_hertz{description=\"Inverter E00000000000002\",device_id=\"E00000000000002\",model=\"AC_Module_Type_E\",module_id=\"P07M20205351\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 59.98\nsunpower_pvs_inverter_operating_frequency_hertz{description=\"Inverter E00000000000003\",device_id=\"E00000000000003\",model=\"AC_Module_Type_E\",module_id=\"P07M20205226\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 59.98\n# HELP sunpower_pvs_inverter_energy_total_watt_hours Total Energy\n# TYPE sunpower_pvs_inverter_energy_total_watt_hours gauge\nsunpower_pvs_inverter_energy_total_watt_hours{description=\"Inverter E00000000000001\",device_id=\"E00000000000001\",model=\"AC_Module_Type_E\",module_id=\"P07M20205372\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 19249.9\nsunpower_pvs_inverter_energy_total_watt_hours{description=\"Inverter E00000000000002\",device_id=\"E00000000000002\",model=\"AC_Module_Type_E\",module_id=\"P07M20205351\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 19313.7\nsunpower_pvs_inverter_energy_total_watt_hours{description=\"Inverter E00000000000003\",device_id=\"E00000000000003\",model=\"AC_Module_Type_E\",module_id=\"P07M20205226\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 18932.5\n# HELP sunpower_pvs_inverter_heatsink_temperature_celcius Heatsink Temperature\n# TYPE sunpower_pvs_inverter_heatsink_temperature_celcius gauge\nsunpower_pvs_inverter_heatsink_temperature_celcius{description=\"Inverter E00000000000001\",device_id=\"E00000000000001\",model=\"AC_Module_Type_E\",module_id=\"P07M20205372\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 22.0\nsunpower_pvs_inverter_heatsink_temperature_celcius{description=\"Inverter E00000000000002\",device_id=\"E00000000000002\",model=\"AC_Module_Type_E\",module_id=\"P07M20205351\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 22.0\nsunpower_pvs_inverter_heatsink_temperature_celcius{description=\"Inverter E00000000000003\",device_id=\"E00000000000003\",model=\"AC_Module_Type_E\",module_id=\"P07M20205226\",port=\"\",software_version=\"118079776\",type=\"SOLARBRIDGE\"} 21.0\n# HELP sunpower_pvs_device_state Device (Component/Module) State\n# TYPE sunpower_pvs_device_state gauge\nsunpower_pvs_device_state{device_id=\"ZT01234567890123456\",device_type=\"PVS\",model=\"PV Supervisor PVS6\",software_version=\"2019.5, Build 4150\",state=\"working\",type=\"\"} 1.0\nsunpower_pvs_device_state{device_id=\"PVS6M01234567p\",device_type=\"Power Meter\",model=\"PVS6M0001p\",software_version=\"3000\",state=\"working\",type=\"PVS5-METER-P\"} 1.0\nsunpower_pvs_device_state{device_id=\"PVS6M01234567c\",device_type=\"Power Meter\",model=\"PVS6M0001c\",software_version=\"3000\",state=\"working\",type=\"PVS5-METER-C\"} 1.0\nsunpower_pvs_device_state{device_id=\"E00000000000001\",device_type=\"Inverter\",model=\"AC_Module_Type_E\",software_version=\"118079776\",state=\"working\",type=\"SOLARBRIDGE\"} 1.0\nsunpower_pvs_device_state{device_id=\"E00000000000002\",device_type=\"Inverter\",model=\"AC_Module_Type_E\",software_version=\"118079776\",state=\"working\",type=\"SOLARBRIDGE\"} 1.0\nsunpower_pvs_device_state{device_id=\"E00000000000003\",device_type=\"Inverter\",model=\"AC_Module_Type_E\",software_version=\"118079776\",state=\"working\",type=\"SOLARBRIDGE\"} 1.0\n```\n\nThe `--use-device-data-timestamp` flag causes the exporter to use the \ntimestamp emitted from the PVS device. This is disabled by default for a few \nreasons:\n\n* Setting the timestamp explicitly (instead of having Prometheus do it) is \nbest suited for the [Push Gateway](https://prometheus.io/docs/practices/pushing/)\n\n* Depending on the component, the timestamp value may be too \"out-of-date\" \n(for example, the Supervisor component refreshes once every 5 minutes only)\n\n* The timestamp field may not be available when the device is in an error state\n\nReferences\n----------\n\nSee the [Notes](sunpower_pvs_notes.md) section for more information.\n\n\nExample Grafana Dashboards\n--------------------------\n\n![Summary Dashboard](docs/summary_screen.png) - [Panel Config](docs/summary_panel_config.json)\n![Inverter Dashboard](docs/inverter_screen.png) - [Panel Config](docs/inverter_panel_config.json)\n![PVS Supervisor Dashboard](docs/pvs_supervisor_panel_config.png) - [Panel Config](docs/pvs_supervisor_panel_config.json) \n\n\n", "description_content_type": "text/markdown", "docs_url": null, "download_url": "", "downloads": { "last_day": -1, "last_month": -1, "last_week": -1 }, "home_page": "https://github.com/ginoledesma/sunpower-pvs-exporter/", "keywords": "sunpower pvs prometheus exporter", "license": "MIT", "maintainer": "", "maintainer_email": "", "name": "sunpower-pvs-exporter", "package_url": "https://pypi.org/project/sunpower-pvs-exporter/", "platform": "", "project_url": "https://pypi.org/project/sunpower-pvs-exporter/", "project_urls": { "Homepage": "https://github.com/ginoledesma/sunpower-pvs-exporter/" }, "release_url": "https://pypi.org/project/sunpower-pvs-exporter/1.0/", "requires_dist": [ "prometheus-client", "requests" ], "requires_python": ">=2.7", "summary": "A Prometheus Exporter for the SunPower PVS Device", "version": "1.0" }, "last_serial": 5317660, "releases": { "1.0": [ { "comment_text": "", "digests": { "md5": "9d8a64a6337b206dc6bd42387fe0871a", "sha256": "bb3d28225287523d19369c1fbdb01809f50f94e8509766c4d6527fb86441e056" }, "downloads": -1, "filename": "sunpower_pvs_exporter-1.0-py2-none-any.whl", "has_sig": false, "md5_digest": "9d8a64a6337b206dc6bd42387fe0871a", "packagetype": "bdist_wheel", "python_version": "py2", "requires_python": ">=2.7", "size": 10245, "upload_time": "2019-05-26T01:08:42", "url": "https://files.pythonhosted.org/packages/9b/ab/2cae1e190ef4ac338ee39fba229e1478e3aecba86a2dbefc6cb0c8a6496a/sunpower_pvs_exporter-1.0-py2-none-any.whl" }, { "comment_text": "", "digests": { "md5": "a83e546e8eb7f45a24605ef16c4d92dc", "sha256": "49b1278d19b8a71e8e24fe54208bd79ce4db0d66c7158c0b203d9d559e3141d7" }, "downloads": -1, "filename": "sunpower_pvs_exporter-1.0-py3-none-any.whl", "has_sig": false, "md5_digest": "a83e546e8eb7f45a24605ef16c4d92dc", "packagetype": "bdist_wheel", "python_version": "py3", "requires_python": ">=2.7", "size": 10246, "upload_time": "2019-05-26T01:08:45", "url": "https://files.pythonhosted.org/packages/27/51/d571363c884f0dad2c9206d090dbeddd33f914516323db1e47263c636ed3/sunpower_pvs_exporter-1.0-py3-none-any.whl" }, { "comment_text": "", "digests": { "md5": "e0794e7ac898edd6bbd506249de2a0cb", "sha256": "623d896054e965c200cb2b03569425f947d4f98d41f5aae1a10c2d44d53cd3c7" }, "downloads": -1, "filename": "sunpower_pvs_exporter-1.0.tar.gz", "has_sig": false, "md5_digest": "e0794e7ac898edd6bbd506249de2a0cb", "packagetype": "sdist", "python_version": "source", "requires_python": ">=2.7", "size": 11578, "upload_time": "2019-05-26T01:08:46", "url": "https://files.pythonhosted.org/packages/bf/a2/bf69e9eae3f8d50b3dbdb6166e7dbcdbbd67644d79c0ecf2292eb2f904ac/sunpower_pvs_exporter-1.0.tar.gz" } ] }, "urls": [ { "comment_text": "", "digests": { "md5": "9d8a64a6337b206dc6bd42387fe0871a", "sha256": "bb3d28225287523d19369c1fbdb01809f50f94e8509766c4d6527fb86441e056" }, "downloads": -1, "filename": "sunpower_pvs_exporter-1.0-py2-none-any.whl", "has_sig": false, "md5_digest": "9d8a64a6337b206dc6bd42387fe0871a", "packagetype": "bdist_wheel", "python_version": "py2", "requires_python": ">=2.7", "size": 10245, "upload_time": "2019-05-26T01:08:42", "url": "https://files.pythonhosted.org/packages/9b/ab/2cae1e190ef4ac338ee39fba229e1478e3aecba86a2dbefc6cb0c8a6496a/sunpower_pvs_exporter-1.0-py2-none-any.whl" }, { "comment_text": "", "digests": { "md5": "a83e546e8eb7f45a24605ef16c4d92dc", "sha256": "49b1278d19b8a71e8e24fe54208bd79ce4db0d66c7158c0b203d9d559e3141d7" }, "downloads": -1, "filename": "sunpower_pvs_exporter-1.0-py3-none-any.whl", "has_sig": false, "md5_digest": "a83e546e8eb7f45a24605ef16c4d92dc", "packagetype": "bdist_wheel", "python_version": "py3", "requires_python": ">=2.7", "size": 10246, "upload_time": "2019-05-26T01:08:45", "url": "https://files.pythonhosted.org/packages/27/51/d571363c884f0dad2c9206d090dbeddd33f914516323db1e47263c636ed3/sunpower_pvs_exporter-1.0-py3-none-any.whl" }, { "comment_text": "", "digests": { "md5": "e0794e7ac898edd6bbd506249de2a0cb", "sha256": "623d896054e965c200cb2b03569425f947d4f98d41f5aae1a10c2d44d53cd3c7" }, "downloads": -1, "filename": "sunpower_pvs_exporter-1.0.tar.gz", "has_sig": false, "md5_digest": "e0794e7ac898edd6bbd506249de2a0cb", "packagetype": "sdist", "python_version": "source", "requires_python": ">=2.7", "size": 11578, "upload_time": "2019-05-26T01:08:46", "url": "https://files.pythonhosted.org/packages/bf/a2/bf69e9eae3f8d50b3dbdb6166e7dbcdbbd67644d79c0ecf2292eb2f904ac/sunpower_pvs_exporter-1.0.tar.gz" } ] }